HiLook Hik-Connect User Guide - Alarm System

- Site/Account Selector: Tap the top-left menu icon to switch between registered sites or accounts.
- Emergency SOS: Provides access to the emergency SOS function, where supported by the device and app configuration. Use this feature only after confirming its operation with your installer.
- Search & Add: Tap the magnifying glass to search for specific devices, or tap the plus icon (+) to scan and add new alarm control panels.
- Overall Arming Status Bar: Displays current system-wide status (e.g., All Armed, Disarmed, or Alarm Triggered) in a color-coded top bar.
- Alarm Panel Header: Shows your custom alarm panel name, quick status indicators (network connectivity, power state, battery status), and the last updated sync timestamp.
- Quick Arming Modes: Instant action buttons to toggle panel states: Stay (Home mode), Disarm (Disables arming), Away (Full system arming), and Silence Alarm (Mutes active sirens/beeps).
- Area / Zone Cards: Displays individual security area cards (e.g., Area 1) along with their current status icon and camera link thumbnail if associated.
- Bottom Navigation Bar: Switch between Home (main dashboard), Control (device management & sharing permissions), and Notifications (event history, alarm triggers, and system fault alerts).

- Position your smartphone camera over the QR code located on the alarm control panel housing, packaging, or Quick Guide.
- QR Code / Bar Code Toggle: Switch mode at the top depending on whether you are scanning a square QR code or a standard linear barcode.
- Help Icon (?): Tap the question mark in the top-right corner to view troubleshooting tips if scanning fails.
- Flashlight Toggle: Tap the torch icon to illuminate QR codes or barcodes in dimly lit installation environments.
- View Help Link: Tap "Can't find the QR code? View Help >" for assistance on locating device codes.
- Album: Tap the image icon to select and scan a saved photo or screenshot of a QR code directly from your gallery.
- Manually Input: Tap the keyboard icon to manually enter the serial number if the physical code is damaged or unreadable.

- Away: Tap Away to Arm.
- The exit countdown will begin, allowing you to leave the premises before the system is fully armed.
- Once the countdown is complete, the panel status will change to Armed.

- Disarm: Tap Disarm.
- Disarming the system will stop the configured alarm output where supported. Check the panel status and event history to confirm the system has returned to its disarmed state.

- Tap the Alarm-Name on the Home Screen to display Zones.
- Device & Area View: From the control panel dashboard, tap the Device tab to view all registered zone sensors and detectors.
- Zone Selection: Tap on a specific zone detector (e.g., Zone 1, Area 1, Device No.: 2) to open its dedicated status screen.
- Detection Status (Detection Mode): Indicates real-time detector status (e.g., Normal, Triggered).
- Lid Status (Tamper Monitoring): Displays tamper cover status (Closed / Open) to ensure sensor enclosure integrity.
- Entry Delay: Shows countdown duration before an entry trigger sound occurs (e.g., 1 min).
- Exit Delay: Displays exit countdown duration allowed after arming the system (e.g., 1 min).
- Bypassed Toggle / Status: Shows whether the zone is currently bypassed (Yes / No). Bypassing allows system arming while leaving specific zones disarmed.
- 24-hour Zone: Displays whether the zone operates continuously 24/7 regardless of arming status.
- Zone Settings: Provides access to advanced configuration options for the selected detector. These settings should only be changed by an authorised person with an understanding of the alarm system.

- Tap the gear icon in the top-right corner of the zone detail screen to configure advanced detector parameters.
- Zone Name & Editing: Access the zone settings screen to rename individual zones (e.g., Zone 1) using the pencil edit icon.
- Main Device Type & Channel No.: Displays hardware configuration details like device type (e.g., Zones Built-in) and channel number.
- Linked Area: Assigns the zone to a specific security partition (e.g., Area 1).
- Detector Type: Configures the peripheral sensor type (e.g., Passive Infrared / PIR).
- Zone Type & Delays: Configure zone behavior such as Delay zones, Entry Delay Time, and Exit Delay Time (with warning notifications if configurations conflict with regional EN50131-1 standards).
- Stay Arm Delay Time: Customizes delay intervals when arming in Stay/Home mode.
- Detector Contact Mode & Dual Zone: Toggle and configure contact modes (e.g., Normally Closed) and dual zone settings.
- Wiring Mode & Pulse Sensitivity: Set physical wiring parameters (e.g., DEOL) and pulse sensitivity thresholds (e.g., 250ms).
- Resistance Settings: Configure alarm resistance and lid open tamper resistance values (e.g., 2.2k).
- Stay Arm Bypass, Chime, & Silent Alarm: Toggle switches for enabling stay arm bypassing, entry/exit chime sounds, or silent alarm triggers.
- Sounder Delay Time & Cross Zone: Adjust siren sounder delay intervals and cross-zone pairing rules.
- Link Pircam: Associate specific PIR camera modules for visual verification when an alarm triggers.

- Click on the Device Name.
- Alarm Panel Info Header: Displays the control panel model preview, device name, direct share icon, and configuration settings gear.
- Main Power Supply: Shows real-time mains AC power status (e.g., Connected / Disconnected).
- Ethernet Connection: Indicates wired LAN network connectivity status (e.g., Connected).
- Battery Status: Displays backup battery health percentage (e.g., 100%).
- Lid Status (Tamper Protection): Shows enclosure lid status (e.g., Closed / Open) to confirm physical tamper integrity.
- Frequency Band: Displays the wireless RF communication operating frequency (e.g., 433MHz).
- Version: Displays current panel firmware release details (e.g., V1.0.80 build 240823).
- Device Serial No.: Shows the unique hardware serial number (SN) for device identification and support.

- Device Info Header: Displays device name (with edit icon), Model number (e.g., HA-ALARM-P48), Serial No. (e.g., Q35862542), and Firmware Version (e.g., V1.0.80 build 240823).
- User Management: Expand this section to manage system access controls:
- User: Configure individual system users, passwords, and user authorization levels.
- Card/Tag: Register and assign RFID keyfobs, proximity cards, or arming tags to authorized users.
- System: Access general panel configuration settings, system time sync, and global operational parameters.
- Network Camera: Pair and link IP cameras to alarm zones for automated video verification upon alarm triggers.
- Area: Configure security partitions, entry/exit delays, and zone grouping across different areas.
- Network & Alarm Communication: Set up Wi-Fi, Ethernet, cellular backup, push notification servers, etc.
- Maintenance: Perform system diagnostics, reboot control panels, back up configurations, or update panel firmware.
- Authorization Service: Manage installer grants, remote maintenance permissions, and service provider access levels.



Related SmartEdge Guides
Explore our other guides to get more from your security system:
- UNV UniEase User Guide - Learn how to use the UniEase mobile app to view and manage your UNV CCTV system.
- HiLook Hik-Connect User Guide - CCTV System - Learn how to view live footage, access recordings and manage your HiLook CCTV system.
- HiLook Hik-Connect User Guide - Alarm System - Learn how to access and manage your HiLook alarm system using the Hik-Connect app.
- CCTV Security Camera Guide - Understand CCTV cameras, recording systems, features and security considerations.
This guide is provided by SmartEdge Automation for general informational and instructional purposes. It is intended to help customers understand and operate compatible products, devices and applications.
SmartEdge Automation is not necessarily the developer or manufacturer of the products, software or applications covered in this guide. Unless expressly stated otherwise, all product names, trademarks and logos belong to their respective owners. References to third-party products and services are for identification and instructional purposes only and do not imply endorsement or affiliation.
Product features, software interfaces, menu options and operating procedures may change between models, software versions and firmware releases. While reasonable efforts are made to maintain the accuracy of this guide, SmartEdge Automation does not warrant that all information is complete, current or applicable to every product or configuration.
Users are responsible for ensuring that products and services are installed, configured and operated securely and in accordance with the manufacturer's instructions and applicable laws. Users should protect their account credentials, access details and device information, and grant access only to authorised persons.
To the extent permitted by law, SmartEdge Automation disclaims liability for loss or damage arising from reliance on this guide, errors or omissions, software changes, device incompatibility or incorrect configuration. Nothing in this disclaimer excludes, restricts or modifies any rights or remedies that cannot lawfully be excluded, restricted or modified under applicable law, including the Australian Consumer Law where applicable.
For product-specific instructions, warranty matters or technical support, please consult the relevant manufacturer or your authorised installer.